  1. CONTROLLING A gas burner with cheap ebay PID - Homebrew Talk

    May 10, 2013 · Using a Honeywell Furnace control valve, has the LP kit with the orifice and spring adjustor, this one runs on 24vac to turn on and off, has a thermopile to detect flame, has a …

  2. PID with two heating elements and how to wire it?

    Apr 9, 2011 · Hello to all of you! I have dilemma on how to connect and wire two heating elements and one PID, I hope someone will help me out with this. This is my setup: Auberins SYL-2352 …

  3. PID controllers with a serial port or WiFi - Homebrew Talk

    Nov 27, 2006 · $109.99 WiFi PID Temperature Control Controller, Relay Output, W/ Dual Alarm, 1/16 DIN Size, AW-SYL-2342 Auber Instruments, Inc $26.99 PID Temperature Controller Kit, …

  4. Step by Step build a 110v portable PID controller

    Dec 21, 2011 · Looks like a second element not under PID control. @sbrbrad which PID controller did you buy and what problems did you have?

  5. Wifi Inkbird ITC-308 fluctuation temps! - Homebrew Talk

    Jan 6, 2008 · I thought about flashing the inkbird with Tasmota with the pid algorithm and trying that https://tasmota.github.io/docs/PID-Control/ Wouldn’t it be contingent on the number of …

  6. MYPIN TA4-SNR Help needed - Homebrew Talk

    Sep 19, 2015 · SOLUTION FOUND. I have built a RIMS 120v single element Temp controller using: TA4-SNR - PID Ruike Electronics Industrial Ltd. SSR-60DA - SSR Same as Fotek K …

  7. DIY PID controller | Homebrew Talk - Beer, Wine, Mead, & Cider …

    Oct 13, 2021 · You cannot control boil vigor with a PID, as it does not run with a fixed output, but rather continuously adjusts output to maintain a target temperature. You need a controller that …

  8. Help the InkBird ITC-100V - Homebrew Talk

    Jan 30, 2013 · Hello friends. I've been putting together a panel based on theelectricbrewery.com with the exception of the PID controllers. I found a deal on the Inkbird ITC-100v which is a …

  9. Between Brews: Controlling Gas Fired Burners - Homebrew Talk

    Oct 4, 2016 · For now, just be aware that any PID circuit you see that uses an SSR to control an electric burner can be changed to solenoid control by (a) eliminating the SSR, (b) switching to …

  10. PID wiring to an SCR voltage regulator? - Homebrew Talk

    Mar 18, 2015 · I'm currently using a digital SCR to control a 3 phase 5500w element in my brew kettle, what i would like to do away with the manual control and have a PID running the …